Description:
The traditional onboard weighing sensors generally use the strain type weighing sensor or load sensor and their output signals are relatively weak, weak signal of late data amplification processing and data stability caused trouble, and our company's patent product star - silicon capacitance macro gravity sensor solves the this a series of problems
Two or more silicon capacitance macro gravity sensor on each axle and axle of the axle housing in a specific part of the installation, when the vehicle in a cargo loading the cargo weight change, the weight change will cause the corresponding deformation axle and axle housing, sensor can accurately induction to the stress and deformation and the deformation into electronic signals, through cable signal transmission to the weighing controller The product is of high stability, good stability, high quality seal and corrosion resistance . It can be directly put into water, oil and other liquid medium can also be compatible with other mine detection system.
Application
Application fields: Logistics vehicle, refuse processing, petrochemical industry, coal mine and etc.
Application vehicles: cement mixer, oil tanker, garbage truck and etc.
Application scenarios: Cargo tracking, road safety, vehicle overloading, vehicle overrun, weighing-calculating charge.
Feature
Measurement load from 100kg to 500t
Non-contact measurement
Stainless steel house, corrosion resistance
Easy installation and remove with mounting bracket
Output signal up to 20mV/V
With antivibration more than 5G/40Hz
Specification
Specs
|
Value
|
Remarks
|
Measurement range
|
100kg-~500t
|
|
Overload
|
150%
|
|
Accuracy
|
±0.1%FS, ±0.5%FS
|
Linearity, repeatability and hysteresis
|
Power supply
|
5VDC
|
Vehicle Terminal System12-24VDC
|
Output signal
|
Digital
|
Analog signal optional
|
Communication interface
|
Aviation plug
|
|
Communication type
|
Standard RS485
|
RS232 optional
|
Protection
|
IP67
|
Special design for IP68
|
Operating temp
|
-30~85
|
|
Required Install QTY
|
Based on the vehicle type
|
1-2pcs each vehicle
|
Dimension
Installation procedures and precautions
1, Installation procedures
1) Confirm the mounting position and quantity
2) Weld the mounting base
3) Confirm the mounting direction
4) Mounting the sensor
5) Connect the sensor
2, Cautions
1) Welding
Make sure the mounting base and the axle housing tight fit, at first fix the 4 corners with spot welding, then weld around.
2) Screw fastening
At first screw the bolt with hand, make sure the contact surface tight fit, then use hexagon spanner alternating right and left to tight enough.
3) Wiring
Connect the sensor according to the wiring code.